Exclusive VIP Kit includes FREE Universal Carrying Case, FREE Mini Plug To Pigtail T/C Lead Set , FREE Toolpack , and FREE Pack of Green Calibration Labels . The one multifunction calibrator you need for all of your process calibrations.
- Value Incentive Package
- LIMITED TIME ONLY! Hurry Offer Ends Soon!
- Temperature Calibrator (745), with FREE Carrying Case (C-101), & FREE T/C Lead Set (22171T), & FREE Toolpak Hanger (TPAK80-4) FREE PST Tool (61010101), & FREE Calibration Labels
- Over $150 Savings
- 725 Can source/simulate volts, mA, RTDs, thermocouples, frequency, and ohms. Measure and source pressure using Fluke 700P series pressure modules. Has Dual display shows input and output. Dual display shows input and output. Programmable step and ramp for automated testing. Powered by 4 AA batteries (25 hours typical operation)
- FREE C-101 Universal Carrying Case! Zippered section holds Multimeters, Single Function Calibrators, etc. Velcro pouch for leads and accessories. Snappable belt loops on back hold up to a 4 wide belt.
- FREE 22171T- JKTE Mini Plug To Pigtail T/C Lead Set
- FREE TPAK80-4 Toolpack -Hang your meter by a magnet or a strap hanger. Locks securely to the meter. Includes 6 strap, 17 strap, and slip on magnet.
- FREE PST Tool- PST Consists of the following all in one! Needlenose and Regular Pliers, Wire Cutters, Hard-Wire Cutters, Clip-Point Knife, Metal/Wood File, 8in/20 cm Ruler, Can/Bottle Opener, [Small, Medium, Large and Phillips] Screwdriver, Awl Punch
- FREE Pack of Green Calibration Labels
>
Each Unit Includes
- Fluke 725
- TL75 Test Leads
- AC70A Test Clips
- One pair of stackable test leads
- Product Overview Manual in 14 different languages
- User Manual on CD-Rom
- TPAK80-4 Took Pack Hanger
- C-101 Carrying Case
- 22171T J,K,T,E Mini T/C Lead Set
- Leatherman PST Tool
- Calibration Labels
>
Measurement Accuracy | ||
Voltage DC | 30.000 V | 0.02% 2 counts (upper display) |
30.000 V | 0.02% 2 counts (lower display) | |
100.00 mV | 0.02% 2 counts | |
-10.00 mV to 75.00 mV | 0.025% 1 count (via TC connector) | |
Current DC | 24.000 mA | 0.02% 2 counts |
Resistance | 0.0 to 400.0 Ω | 0.1 Ω (4-wire), 0.15 Ω (2- and 3-wire) |
401 to 1500 Ω | 0.5 Ω (4-wire), 1 Ω (2- and 3-wire) | |
1500 to 3200 Ω | 1 Ω (4-wire), 1.5 Ω (2- and 3-wire) | |
Frequency | 2.0 to 1000.0 CPM | 0.05% 1 count |
1.0 to 1100.0 Hz | 0.05% 1 count | |
1.00 to 10.00 kHz | 0.05% 1 count | |
Sensitivity | 1 V peak-to-peak-minimum | |
Pressure | Accuracy from 0.025% of range using any of 29 pressure modules (for detailed specifications refer to pressure modules in options and accessories). Modules available for differential, gauge, vacuum, absolute, dual and high pressure. | |
Source Accuracy | ||
Voltage DC | 100.00 mV | 0.02% 2 counts |
10.000 V | 0.02% 2 counts | |
-10.00 mV to 75.00 mV | 0.025% 1 count (via TC connector) | |
Current DC | 24.000 mA (source) | 0.02% 2 counts |
24.000 mA (simulate) | 0.02% 2 counts | |
Resistance | 15.0 to 400.0 Ω | 0.15 Ω (exc. current 0.15 to 0.5 mA), 0.1 Ω (exc. current 0.5 to 2 mA) |
401 to 1500 Ω | 0.5 Ω (excitation current 0.05 to 0.8 mA) | |
1500 to 3200 Ω | 1 Ω (excitation current 0.05 to 0.4 mA) | |
Frequency | 2.0 to 1000.0 CPM | 0.05% |
1.0 to 1100.0 Hz | 0.05% | |
1.00 to 10.00 kHz | 0.25% | |
Waveform | 5 V p-p squarewave, -0.1 V offset | |
RTDs and Thermocouples | ||
Measure accuracy | NI-120 | 0.2°C |
PT-100 (385) | 0.33°C | |
PT-100 (393) | 0.3°C | |
PT-100 (JIS) | 0.3°C | |
PT-200 (385) | 0.2°C | |
PT-500 (385) | 0.3°C | |
PT-1000 (385) | 0.2°C | |
Resolution | 0.1°C | |
J | 0.7°C | |
K | 0.8°C | |
T | 0.8°C | |
E | 0.7°C | |
R | 1.8°C | |
S | 1.5°C | |
B | 1.4°C | |
L | 0.7°C | |
U | 0.75°C | |
N | 0.9°C | |
Resolution | J, K, T, E, L, N, U: 0.1°C, 0.1°F B, R, S: 1°C, 1°F | |
XK | 0.6°C | |
BP | 1.2°C | |
Source accuracy | NI-120 | 0.2°C |
PT-100 (385) | 0.33°C | |
PT-100 (393) | 0.3°C | |
PT-100 (JIS) | 0.3°C | |
PT-200 (385) | 0.2°C | |
PT-500 (385) | 0.3°C | |
PT-1000 (385) | 0.2°C | |
Resolution | 0.1°C | |
Accuracy stated for 4-wire measurement. | ||
J | 0.7°C | |
K | 0.8°C | |
T | 0.8°C | |
E | 0.7°C | |
R | 1.4°C | |
S | 1.5°C | |
B | 1.4°C | |
L | 0.7°C | |
U | 0.75°C | |
N | 0.9°C | |
Resolution | J, K, T, E, L, N, U: 0.1°C, B, R, S: 1°C | |
XK | 0.6°C | |
BP | 1.2°C | |
Specifications | ||
Ramp functions | Source functions | Voltage, current, resistance, frequency, temperature |
Ramps | Slow ramp, Fast ramp, 25% step-ramp | |
Loop power function | Voltage | 24 V |
Accuracy | 10% | |
Maximum current | 22 mA, short circuit protected | |
Step functions | Source functions | Voltage, current, resistance, frequency, temperature |
Steps | 25% of range, 100% of range | |
Environmental Specifications | ||
Operating temperature | -10°C to 55°C | |
Storage temperature | -20°C to 71°C | |
Operating altitude | 3000 m | |
Safety Specifications | ||
Agency approvals | EN 61010-1:1993, ANSI/ISA S82.01-1994, CAN/CSA C22.2 No 1010.1:1992 | |
Mechanical and General Specifications | ||
Size | 130 x 236 x 61 mm | |
Weight | 0.65 kg | |
Batteries | 4 AA alkaline batteries | |
Battery replacement | Separate battery compartment, accessable without breaking calibration seal | |
Side port connections | Pressure module connector, also used for remote real-time programming |