- Select from five modules to customize the four channels as you need it
- Anyone can use this meter with its plain language screen prompts, soft keys that update for easy selection and a multilanguage interface that supports English, Spanish, French, Italian, German and Chinese
- Non-volatile memory holds up to 2000 data points with time and date stamp
- Data transfer and updating meter software is easy with two USB and RS232 ports
- Includes data analysis software for transferring stored results or displaying readings in real-time
- Mix samples without a stir plate with direct control for two Orion Star stirrer probes (096019, sold separately)
- Included electrode arm and newly-designed probe holder make it easier to maintain and place probes into samples
- Works with almost every AC power source with the included universal power adapter
- IP54-rated housing handles splashes
- Three year meter replacement warranty
- Range -2.000 to 20.000
- Resolution 0.1, 0.01, 0.001
- Relative Accuracy ±0.002
- Calibration Points up to 6
- Range 0 to 19999 in ppm, M, mg/L, %, ppb or unitless
- Resolution up to 4 significant digits
- Relative Accuracy ±0.2 mV or ±0.5% of reading, whichever is greater
- Calibration Points up to 6, Calibration point editing, timed end point, linear point to point, non-linear selectable auto-blank, low concentration range stability, adjustable ISO point
- Range ±2000.0
- Resolution 0.1
- Relative Accuracy ±0.2 mV or ±0.05% of reading whichever is greater
- Calibration Points 1
- Range -5 to 105
- Resolution 0.1
- Relative Accuracy ±0.1
- Concentration Range Polarographic: 0 to 90mg/L, 0 to 600%, RDO optical: 0 to 50mg/L, 0 to 500%
- Concentration Resolution 0.01, 0.1
- Relative Accuracy Polarographic: ±0.2mg/L, ±2% RDO optical: ±0.1mg/L up to 8mg/L, ±0.2mg/L up to 20mg/L, 10% of reading beyond, ±2%
- Calibration Water-saturated air, air-saturated water, manual (Winkler) and zero point
- Range 0.00 to 3000 mS
- Resolution 0.01 uS minimum, 4 significant figures minimum
- Relative Accuracy 0.5% reading ±1 digit
- Calibration Points up to 5
- Inputs BNC, reference pin, two 8-pin mini-DIN, 9-pin mini-DIN, two stirrer ports
- Data Management 2000 points with date/time stamp
- Output RS-232, USB
- Display Color, graphic LCD, user-customizable display
- Warranty Period 3-year meter replacement
Shop By Department
- Calibration Instruments
- Dimensional Measuring Tools
- Electrical Test Instruments
- Environmental Testing
- Power Quality
- Pressure Measurement
- Preventative/Maintenance
- Process Instruments
- Recorders/Data Loggers
- Scales and Balances
- Temperature Measurement
- Torque
- Oscilloscopes
- Power Supplies
- Spectrum Analyzers